Abstract:
In this note we present the analytical equations for ionization cooling performance
and apply them to recently developed storage ring cooling systems designed to cool muons
transversely and longitudinally. Expected cooling properties are calculated and variations
that may improve cooling performance are discussed.
Posted muc0227.pdf to WWW
Posted by Neuffer
Files in Document:
Other Files:
Keywords:
COOL_THEORY
Notes and Changes:
David Neuffer