Abstract:
The magnetic field induced by the superconducting solenoid at MTA may destroy the PMTs in x-ray detectors. The Mu-Metal only seems inadequate to provide required shielding for the detectors closest to the solenoid. Therefore soft-iron tubes are proposed to add additional shielding to those detectors. Simulations via OPERA show this method may work.