We examine the use of low-beta bucked coil lattices for 6D and final cooling for the muon collider. A straight tapered channel cools the transverse normalized emittance from 1.01 to 0.12 mm with 34% transmission. Possible causes for the large transmission losses are examined. Using a matrix transformation corresponding to ideal emittance exchange only increased the transmission to 37%. Ring configurations examined so far have worse performance.